Home
Welcome to the Case IH Advanced Farming Systems (AFS) North American customer website. This site contains answers to many frequently asked questions about Case IH AFS systems, along with downloads and other reference information. Don't see an answer to your question? Contact your local Case IH dealer or the AFS Customer Support Center!
If you're new to AFS, we invite you to start with the Overview.
----------
The list below displays questions and answers across all categories, with the most recent questions listed first. To view questions and answers by category, please select a category from the navigation menu on the left.
The most common cause for missing planter seed graphs on run screens of the Pro 600 is improper configuration settings for rows.
Go to Toolbox > Config, and be sure the "Section x Rows" windows are populated with the correct number of planter row units per section.
However, the monitor will also accept 19.2k. Some users have reported issues with slower baud rates. Other settings are as follows:
The correct connection type is dependent on how the GPS receiver is connected to the vehicle or display.
CAN A: Use this connection when utilizing the GPS receiver connection on a factory installed AccuGuide ready tractor or sprayer. Used on Generic Tractor, Magnum Tractors, PUMA Tractors, Steiger Tractors, Axial-Flow 2500 Series.
CAN B: Use this connection on 88 Series combines, Axial-Flow 7010/8010 combines, and 20 Series combines, for factory-installed GPS receivers or any receiver installed on the vehicle's secondary CAN bus.
RS232A: Use if connecting any GPS receiver to the flat 5-pin connection on a 2100/2300/2500 series combine or universal tractor/planter harness. This setting is also used when connecting a serial receiver to the 10-pin connector on an 88 Series combine, AF 7010/8010 combine, or 20 Series combine.
RS232B: Use if connecting any GPS receiver to the serial connection on the bottom of the Pro600. IMPORTANT: This connector does not provide a ground for the data signal. If you experience difficulty establishing communication via the RS232B connection, contact your local Case IH dealer.
An operator's manual is available from your local Case IH dealer. Ask for document "Rac 9-28542".
A quick start card (document number 7-85860) is also available. These documents are both for version 6.02 from October, 1997. Finally, a key press guide is available on our Downloads page. Download the Keypad Functions Document.
